Detection and quantitative determination of chlortalidone (Hygroton®) in urine

CAMAG

Chlortalidone is an often used diuretic for the therapy. Moreover, it is abused in sports for doping purposes and is therefore on the IOC (Int. Olymp. Committee) list of banned drugs.
The alkaline urine extract is chromatographed on silica gel. Post chromatographic derivatization (with formaldehyde/sulfuric acid reagent) converts chlortalidone into a yellow dye. Results can be verified by UV absorbance spectra of the underivatized substances. Densitometric quantification is performed by absorbance at 240 nm. Determination limit is 0.2 mg/L, reliable detection limit about 0.1 mg/L.

Stiahnuť aplikáciu Stiahnuť aplikáciu K prehľadu aplikácií Kontaktujte nás

Formulár na stiahnutie aplikácie

* Tieto polia sú povinné.

** Upozorňujeme, že vaše osobné údaje budú uložené bezpečne a v súlade so všeobecným nariadením o ochrane osobných údajov (GDPR) (EÚ) 2016/679 o ochrane osôb vo vzťahu k spracovaniu osobných údajov a voľnému pohybu týchto údajov. Máte právo požadovať od nás prístup k vašim uloženým osobným údajom, opraviť, vymazať alebo obmedziť spracovanie osobných údajov a kedykoľvek odvolať svoj súhlas. Osobné údaje nebudú zdieľané mimo našu skupinu spoločností ani predávané iným spoločnostiam. Osobné údaje môžu byť použité pre marketingové a komunikačné účely až do zrušenia súhlasu.